150 research outputs found

    Book Review

    Get PDF

    CT dose reduction in children

    Get PDF
    World wide, the number of CT studies in children and the radiation exposure by CT increases. The same energy dose has a greater biological impact in children than in adults, and scan parameters have to be adapted to the smaller diameter of the juvenile body. Based on seven rules, a practical approach to paediatric CT is shown: Justification and patient preparation are important steps before scanning, and they differ from the preparation of adult patients. The subsequent choice of scan parameters aims at obtaining the minimal signal-to-noise ratio and volume coverage needed in a specific medical situation; exposure can be divided in two aspects: the CT dose index determining energy deposition per rotation and the dose-length product (DLP) determining the volume dose. DLP closely parallels the effective dose, the best parameter of the biological impact. Modern scanners offer dose modulation to locally minimise exposure while maintaining image quality. Beyond the selection of the physical parameters, the dose can be kept low by scanning the minimal length of the body and by avoiding any non-qualified repeated scanning of parts of the body. Following these rules, paediatric CT examinations of good quality can be obtained at a reasonable cost of radiation exposur

    Image quality of supine chest radiographs: intra-individual comparison of computed radiography and low-dose linear-slit digital radiography

    Get PDF
    The purpose of this retrospective study was to intra-individually compare the image quality of computed radiography (CR) and low-dose linear-slit digital radiography (LSDR) for supine chest radiographs. A total of 90 patients (28 female, 62 male; mean age, 55.1years) imaged with CR and LSDR within a mean time interval of 2.8days ± 3.0 were included in this study. Two independent readers evaluated the image quality of CR and LSDR based on modified European Guidelines for Quality Criteria for chest X-ray. The Wilcoxon test was used to analyse differences between the techniques. The overall image quality of LSDR was significantly better than the quality of CR (9.75 vs 8.16 of a maximum score of 10; p < 0.001). LSDR performed significantly better than CR for delineation of anatomical structures in the mediastinum and the retrocardiac lung (p < 0.001). CR was superior to LSDR for visually sharp delineation of the lung vessels and the thin linear structures in the lungs. We conclude that LSDR yields better image quality and may be more suitable for excluding significant pathological features of the chest in areas with high attenuation compared with C

    CT dose reduction in children

    Get PDF

    Book Review

    Get PDF

    Ear pain in patients with oropharynx carcinoma: how MRI contributes to the explanation of a prognostic and predictive symptom

    Get PDF
    Reflex otalgia is a predictive and prognostic parameter for local control in patients with oropharynx carcinoma. Can a morphologic correlate of this important symptom be detected by MRI? Thirty-six patients were prospectively evaluated by MRI before radical radiotherapy. Sixteen patients had reflex otalgia; 20 did not. The oropharynx and adjacent regions were analyzed. Alteration was defined as effacement of anatomical structures, signal alteration or enhancement after contrast medium administration. The χ 2-test was used to compare categorical parameters. In patients with reflex otalgia, alteration of the following structures innervated by the glossopharyngeal nerve were found significantly more often: nasopharynx, hard palate, superior constrictor pharyngis muscle, palatine tonsil, palatopharyngeus muscle, palatoglossus muscle, stylopharyngeus muscle, hyoglossus muscle and preepiglottic space. No difference was found for the muscles of mastication, levator and tensor veli palatini muscles, styloglossus muscle, genioglossus muscle, intrinsic muscles of the tongue, digastric muscles, mucosal surface of the lateral and posterior pharyngeal wall, uvula, valleculae, parapharyngeal space and larynx. An alteration of structures innervated by the glossopharyngeal nerve was visualized on MRI significantly more often when reflex otalgia was present. Involvement of structures innervated by other cranial nerves did not show the same association with ear pai

    Detection of hepatic portal venous gas: its clinical impact and outcome

    Get PDF
    The clinical impact and outcome of a rare radiographic finding of hepatic portal venous gas (HPVG) as well as the effectiveness of computed tomography (CT), CT scanogram, and conventional radiography in the detection of HPVG were retrospectively analyzed. CT scans, CT scanogram, and plain film radiographs of 11 patients with HPVG were reviewed and compared with their medical records and surgical and pathology reports. Eight of the 11 patients underwent plain film radiographs 1day before or after the CT scan. HPVG was detected at CT in all 11 patients, on CT scanogram in three (3 of 11, 27.3%), and on plain films in one (one of eight, 12.5%). In nine of 11 patients (81.8%), CT revealed an associated pneumatosis intestinalis. In six of the 11 patients (54.6%), acute mesenteric ischemia was the underlying disease for HPVG. Seven patients (63.6%) underwent emergency exploratory laparotomy. The mortality rate for HPVG alone was 27.3% (3 of 11) and for HPVG related to mesenteric bowel disease 50% (three of six). Acute mesenteric ischemia is the most common cause of HPVG, which continues to have a predictably higher mortality. CT is superior to CT scanograms and radiographs in the detection of HPVG and its underlying diseases and, therefore, should be used as the primary diagnostic too

    Importance of extracolonic findings at IV contrast medium-enhanced CT colonography versus those at non-enhanced CT colonography

    Get PDF
    To compare the clinical importance of extracolonic findings at intravenous (IV) contrast-enhanced CT colonography versus those at non-enhanced CT colonography. IV contrast medium-enhanced (n=72) and non-enhanced (n=30) multidetector CT colonography was performed in 102 symptomatic patients followed by conventional colonoscopy on the same day. The impact of extracolonic findings on further work up and treatment was assessed by a review of patient records. Extracolonic findings were divided into two groups: either leading to further work up respectively having an impact on therapy or not. A total of 303 extracolonic findings were detected. Of those, 71% (215/303) were found on IV contrast-enhanced CT, and 29% (88/303) were found on non-enhanced CT colonography. The extracolonic findings in 25% (26/102) of all patients led to further work up or had an impact on therapy. Twenty-two of these patients underwent CT colonography with IV contrast enhancement, and four without. The percentage of extracolonic findings leading to further work up or having an impact on therapy was higher for IV contrast-enhanced (31%; 22/72) than for non-enhanced (13%; 4/30) CT scans (P=0.12). IV contrast-enhanced CT colonography produced more extracolonic findings than non-enhanced CT colonography. A substantially greater proportion of findings on IV contrast-enhanced CT colonography led to further work up and treatment than did non-enhanced CT colonograph

    A novel multiple-trauma CT-scanning protocol using patient repositioning

    Get PDF
    Emergency CT examination is considered to be a trade-off between a short scan time and the acceptance of artifacts. This study evaluates the influence of patient repositioning on artifacts and scan time. Eighty-three consecutive multiple-trauma patients were included in this prospective study. Patients were examined without repositioning (group 1, n=39) or with patient rotation to feet-first with arms raised for scanning the chest and abdomen/pelvis (group 2, n=44). The mean scan time was 21min in group 1 and 25min in group 2 (P=0.01). The mean repositioning time in group 2 was 8min. Significantly, more artifacts were observed in group 1 (with a repeated scan in 7%) than in group 2 (P=0.0001). This novel multiple- trauma CT-scanning protocol with patient repositioning achieves a higher image quality with significantly fewer artifacts than without repositioning but increases scan time slightl
    • …
    corecore